House drainage pipe system for HT pipes and fittings
The house drainage pipe system brings together straight HT pipes, bends, branches, sockets, plugs, and seals for domestic drainage. The key selection criteria are nominal diameter, angle, pipe length, and connection type. The following notes arrange the components by these features and show which details can be found in the product data.
Compare nominal diameter first
Selection in the house drainage pipe system starts at the existing connection. The subcategories arrange the components by DN/OD 32, 40, 50, 75, 90, 110, 125, and 160. This makes it possible to match the nominal diameter first, before the component shape is determined. Straight pipes form a run, bends change its direction, and branches bring additional pipe connections together. Sockets, sleeves, and plugs serve different connection and termination tasks. In addition to nominal diameter, angle, length, and connection type are therefore further selection points.
The ranges listed cover different pipe sizes; a product with DN/OD 50 is not replaced by a part with DN/OD 75. For transitions with two or three sizes, the complete notation is decisive, such as 75/50 or 110/110/110.
One of the listed nominal diameters for smaller pipe connections.
Selection range for pipes and fittings in this category.
Suitable range for straight pipes, sockets, bends, and branches with this specification.
Selection range for pipe sections and fittings with a larger nominal diameter.
Straight pipes by length and connection
Straight pipe sections form the basis of a line. The product details give the nominal diameter and length sometimes in DN notation and sometimes as DN/OD with a measurement. For comparison, always consider the complete combination of nominal diameter and length. The pipe designation alone is not enough when several variants share the same nominal diameter.
Short pipe sections
The HTsafeEM pipe DN/OD 50 x 500 mm is listed as a straight section weighing 0.18 kg. For the HT pipe 110, the product card gives DN/OD 110 x 150 and 0.25 kg. Such measurements help distinguish short runs from connection areas.
Longer pipe sections
For DN 75, an HT pipe is described with a length of 1000 mm and a weight of 0.5 kg. Comparing it with the existing pipe route shows whether one section is sufficient or whether connections and additional pipe lengths must be planned.
Bends, branches, and changes of direction
Fittings differ mainly in their purpose and the specified angle. A bend guides a line in another direction, while a branch connects an additional route. The following three cards show different details from the product data and make comparison by shape, nominal diameter, angle, and weight tangible.
Bend DN/OD 110, 15 degrees
This fitting is specified as DN/OD 110 and 15 degrees. Its weight is 0.17 kg.
Pipe DN/OD 50 x 500 mm
This straight HTsafeEM pipe is specified as DN/OD 50 x 500 mm and 0.18 kg.
Branch DN/OD 75/75, 87 degrees
The branch is specified as DN/OD 75/75 and 87 degrees; its weight is 0.15 kg.
Connections with sockets and transitions
Sockets show how pipe sections are connected or closed. The product details list double socket, long socket, push-on socket, and slip socket as separate designations. The HTsafeMM double socket is described as DN/OD 50. The specifications list long sockets in DN/OD 40 and DN/OD 75. The HTsafeAM push-on socket DN/OD 75 is mentioned with a sleeve; the HTsafeU slip socket also has DN/OD 75.
For a transition to cast iron, the category lists the HTsafeUG connection DN/OD 75. An HT socket plug DN/OD 75 is designated as a plug for a wastewater pipe. Another point of comparison is the double socket DN/OD 50 weighing 0.05 kg. This allows connection type and nominal diameter to be considered separately.
Classify branches by connection and angle
For a branch, the connection specifications and angle belong together. The HTsafeDA fitting is described as DN/OD 50/50/50 and 67 degrees. Another branch bears the specification DN/OD 75/50 with 67 degrees. For DN/OD 75/75, an angle of 87 degrees is given. The HTsafeDA double branch DN/OD 110/110/110 is also listed with 67 degrees in the product data.
The notation 75/50 or 110/110/110 shows which connection sizes meet in the fitting. The angle distinguishes variants with similar nominal diameters. For matching an existing setup, both details must therefore be carried over before a branch is combined with a straight pipe or a bend.
Seals, sleeves, and plugs
Seals and sleeves are separate selection parts within the system. The HTsafeMM double socket DN/OD 50 is listed with a replaceable NBR seal. The HTsafeUG connection DN/OD 75 also includes a replaceable NBR seal in its details. The HTsafeAM push-on socket DN/OD 75 is described with a sleeve.
The HT socket plug DN/OD 75 lists polypropylene as its material. Polypropylene is also specified for individual fittings, while other product cards focus mainly on nominal diameter, angle, or connection type. For a suitable combination, the specific nominal diameter and the designation of the sealing part therefore remain decisive.
Nominal diameter is also the starting point when assigning replacement parts. A DN/OD 75 sealing ring does not automatically belong to a connection with a different nominal diameter. The designation of a sleeve, NBR seal, or plug should be read together with the specific connection. This prevents the sealing part from being confused with the pipe fitting.
Installation planning without detours
A fixed sequence makes it easier to assemble the components:
- Record the nominal diameter: Match the specification on the existing pipe with the appropriate DN/OD subcategory.
- Determine the component shape: Classify a pipe for a straight run, a bend for a change of direction, and a branch for an additional connection.
- Match the angle: Do not replace specifications such as 15, 30, 67, or 87 degrees with similar values.
- Compare the length: For straight pipes, read the complete measurement, such as DN 75 x 1000 mm or DN/OD 50 x 500 mm.
- Add the connection: Assign a double socket, long socket, push-on socket, slip socket, sleeve, or plug according to the specific connection task.
This keeps the selection clear: first the nominal diameter, then the shape, followed by angle and length, and finally the connection or closure.
When several components are involved, a short list is useful: existing nominal diameter, required angle, necessary length, transition, and seal. These five details prevent a fitting from being assigned solely because its product name sounds similar. For branches, add the individual connection sizes; for straight pipes, the complete length specification is important. This keeps the setup comprehensible even when different pipe sections are combined.
Questions before selection
The most common questions can be answered using the designations and the stated product data.
Which nominal diameters belong to the house drainage pipe system?
The subcategories list DN/OD 32, 40, 50, 75, 90, 110, 125, and 160. For matching, the specification at the existing connection matters, not just the shape of the required component.
What distinguishes a pipe from a bend or branch?
A pipe is designated as a straight section. A bend carries an angle specification for a change of direction. A branch also states the connection sizes, for example DN/OD 75/50 or DN/OD 110/110/110.
Which lengths are specified for straight pipes?
The product details include DN/OD 50 x 500 mm, DN 75 x 1000 mm, and DN/OD 110 x 150. One product card also states a weight of 0.18 kg for the DN/OD 50 x 500 mm pipe and 0.5 kg for the DN 75 x 1000 mm pipe.
What do double socket, long socket, and slip socket mean?
These are separate designations for connection parts. The product data list a DN/OD 50 double socket, DN/OD 40 and 75 long sockets, and a DN/OD 75 slip socket. The designation distinguishes the connection type.
Which materials are mentioned?
Polypropylene is named for the HT socket plug DN/OD 75 and for individual fittings. Other articles focus on nominal diameter, angle, length, or sealing. A material specification should therefore be taken from the respective product card.
Is there a connection to cast iron?
Yes, the product data list an HTsafeUG connection to cast iron with DN/OD 75. This term describes a separate transition type and should be matched with the nominal diameter of the existing connection.